|
|
Registros recuperados : 2 | |
1. | | RODRIGUES, R. A.; MENESES, I. I. F. S.; JORGE, K. S. G.; SILVA, M. R.; SANTOS, L. R. dos; LILENBAUM, W.; ETGES, R. N.; ARAUJO, F. R. False-negative reactions to the comparative intradermal tuberculin test for bovine tuberculosis. Pesquisa Veterinária Brasileira, Brasília, DF, v. 37, n. 12, p. 1380-1384, dezembro. 2017. Título em português: Reações falso-negativas ao teste cervical comparativo para tuberculose bovina. Biblioteca(s): Embrapa Gado de Corte; Embrapa Unidades Centrais. |
| |
2. | | RODRIGUES, R. A.; MENESES, I. I. F. S.; JORGE, K. S. G.; LEGUIZAMON, G. O. de C.; SILVA, M. R.; RAMOS C. A. N.; SANTOS, L. R. dos; LILENBAUM. W.; ETGES, R. N.; ARAUJO, F. R. Reações falso-negativas ao teste cervical comparativo para tuberculose bovina. Brasília, DF: Embrapa, 2017. 30 p. (Embrapa Gado de Corte. Boletim de pesquisa e desenvolvimento, 38). Biblioteca(s): Embrapa Gado de Corte. |
| |
Registros recuperados : 2 | |
|
|
Registro Completo
Biblioteca(s): |
Embrapa Gado de Corte; Embrapa Unidades Centrais. |
Data corrente: |
21/03/2018 |
Data da última atualização: |
23/03/2018 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
A - 2 |
Autoria: |
RODRIGUES, R. A.; MENESES, I. I. F. S.; JORGE, K. S. G.; SILVA, M. R.; SANTOS, L. R. dos; LILENBAUM, W.; ETGES, R. N.; ARAUJO, F. R. |
Afiliação: |
Rudielle A. Rodrigues, Programa de Pós-Graduação em Ciências Veterinárias/Faculdade de Medicina Veterinária e Zootecnia - FAMEZ/Universidade Federal de Mato Grosso do Sul - UFMS; Ingrid I. F. S. Meneses, Programa de Pós-Graduação em Biotecnologia e Biodiversidade da Região Centro-Oeste/Universidade Federal de Mato Grosso do Sul - UFMS; Klaudia S. G. Jorge, Programa de Pós-Graduação em Ciências Veterinárias/Faculdade de Medicina Veterinária e Zootecnia - FAMEZ/Universidade Federal de Mato Grosso do Sul - UFMS; MARCIO ROBERTO SILVA, CNPGL; LENITA RAMIRES DOS SANTOS, CNPGC; Walter Lilenbaum, Laboratório de Bacteriologia Veterinária/Universidade Federal Fluminense - UFF; Rodrigo N. Etges, Secretaria da Agricultura/Pecuária e Irrigação; FLABIO RIBEIRO ARAUJO, CNPGC. |
Título: |
False-negative reactions to the comparative intradermal tuberculin test for bovine tuberculosis. |
Ano de publicação: |
2017 |
Fonte/Imprenta: |
Pesquisa Veterinária Brasileira, Brasília, DF, v. 37, n. 12, p. 1380-1384, dezembro. 2017. |
Idioma: |
Inglês |
Notas: |
Título em português: Reações falso-negativas ao teste cervical comparativo para tuberculose bovina. |
Conteúdo: |
According to the Brazilian National Program for the Control and Eradication of Animal Brucellosis and Tuberculosis (PNCEBT), the routine tests for the diagnosis of bovine tuberculosis in the country are the simple intradermal tuberculin test (SITT) of the Ministry of Agriculture, Livestock and Food Supply (MAPA), the caudal fold test and the comparative intradermal tuberculin test (CITT). The latter is also used as a confirmatory test. A group of 53 animals from three dairy herds in a focal area for bovine tuberculosis, that were submitted to depopulation in the state of Rio Grande do Sul, were submitted to the CITT. Tissues were cultured and the resulting colonies were confirmed by PCR and DNA sequencing. Among the 53 animals analyzed using the CITT, 32 (60.4%) were negative, 14 (26.4%) were positive and seven (13.2%) results were inconclusive. The CITT detected 11 of the 39 animals with culture-confirmed M. bovis infection as positive. Among the total of 14 uninfected animals based on cultures, the CBT detected eight as negative. Thus, the CITT demonstrated sensitivity of 28.2% and specificity of 57.1% for the population sampled. A total of 24/32 (75.0%) of the animals with negative CITT results were culture positive (confirmed by PCR) and were considered false negatives based on the CITT. The maintenance of these false-negative animals in herds has serious implications for the control of the disease, since they can be a source of infection. The addition of complementary tests could help identify such animals and increase the odds of diagnostic success. MenosAccording to the Brazilian National Program for the Control and Eradication of Animal Brucellosis and Tuberculosis (PNCEBT), the routine tests for the diagnosis of bovine tuberculosis in the country are the simple intradermal tuberculin test (SITT) of the Ministry of Agriculture, Livestock and Food Supply (MAPA), the caudal fold test and the comparative intradermal tuberculin test (CITT). The latter is also used as a confirmatory test. A group of 53 animals from three dairy herds in a focal area for bovine tuberculosis, that were submitted to depopulation in the state of Rio Grande do Sul, were submitted to the CITT. Tissues were cultured and the resulting colonies were confirmed by PCR and DNA sequencing. Among the 53 animals analyzed using the CITT, 32 (60.4%) were negative, 14 (26.4%) were positive and seven (13.2%) results were inconclusive. The CITT detected 11 of the 39 animals with culture-confirmed M. bovis infection as positive. Among the total of 14 uninfected animals based on cultures, the CBT detected eight as negative. Thus, the CITT demonstrated sensitivity of 28.2% and specificity of 57.1% for the population sampled. A total of 24/32 (75.0%) of the animals with negative CITT results were culture positive (confirmed by PCR) and were considered false negatives based on the CITT. The maintenance of these false-negative animals in herds has serious implications for the control of the disease, since they can be a source of infection. The addition of complementary t... Mostrar Tudo |
Palavras-Chave: |
Bacteriological culture; Cultura bacteriológica; Reações falso-negativas; Teste Cervical Comparativo; Tuberculose bovina. |
Thesagro: |
Mycobacterium Bovis. |
Thesaurus NAL: |
Tuberculosis. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/174398/1/False-negative-reactions-to-the-comparative.pdf
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/174263/1/False-negative-reactions-to-the-comparative.pdf
|
Marc: |
LEADER 02625naa a2200301 a 4500 001 2089602 005 2018-03-23 008 2017 bl uuuu u00u1 u #d 100 1 $aRODRIGUES, R. A. 245 $aFalse-negative reactions to the comparative intradermal tuberculin test for bovine tuberculosis.$h[electronic resource] 260 $c2017 500 $aTítulo em português: Reações falso-negativas ao teste cervical comparativo para tuberculose bovina. 520 $aAccording to the Brazilian National Program for the Control and Eradication of Animal Brucellosis and Tuberculosis (PNCEBT), the routine tests for the diagnosis of bovine tuberculosis in the country are the simple intradermal tuberculin test (SITT) of the Ministry of Agriculture, Livestock and Food Supply (MAPA), the caudal fold test and the comparative intradermal tuberculin test (CITT). The latter is also used as a confirmatory test. A group of 53 animals from three dairy herds in a focal area for bovine tuberculosis, that were submitted to depopulation in the state of Rio Grande do Sul, were submitted to the CITT. Tissues were cultured and the resulting colonies were confirmed by PCR and DNA sequencing. Among the 53 animals analyzed using the CITT, 32 (60.4%) were negative, 14 (26.4%) were positive and seven (13.2%) results were inconclusive. The CITT detected 11 of the 39 animals with culture-confirmed M. bovis infection as positive. Among the total of 14 uninfected animals based on cultures, the CBT detected eight as negative. Thus, the CITT demonstrated sensitivity of 28.2% and specificity of 57.1% for the population sampled. A total of 24/32 (75.0%) of the animals with negative CITT results were culture positive (confirmed by PCR) and were considered false negatives based on the CITT. The maintenance of these false-negative animals in herds has serious implications for the control of the disease, since they can be a source of infection. The addition of complementary tests could help identify such animals and increase the odds of diagnostic success. 650 $aTuberculosis 650 $aMycobacterium Bovis 653 $aBacteriological culture 653 $aCultura bacteriológica 653 $aReações falso-negativas 653 $aTeste Cervical Comparativo 653 $aTuberculose bovina 700 1 $aMENESES, I. I. F. S. 700 1 $aJORGE, K. S. G. 700 1 $aSILVA, M. R. 700 1 $aSANTOS, L. R. dos 700 1 $aLILENBAUM, W. 700 1 $aETGES, R. N. 700 1 $aARAUJO, F. R. 773 $tPesquisa Veterinária Brasileira, Brasília, DF$gv. 37, n. 12, p. 1380-1384, dezembro. 2017.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Gado de Corte (CNPGC) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|